Park Audio™
PD 332
Power distributor
Application:
supply voltage distribution between consumers in RACKs.
- Power Requirements – three-phase with grounding.
- Input connector – panel plug CEE 35A 5p 6h.
- 3 output panel power sockets – type «Shuko», 16 A / 250 V (PCE, stage series «Midnight»).
- 3 blocks of output terminals – LNE (phase, zero, ground phase).
- Individual protective circuit breaker for each phase.
- 3 network indicators (individual for each phase).
- Additional(AUX) power socket («Shuko» type, 16 A/250 V, PCE, stage series «Midnight») with protective citcuit breaker.
- Design for installation into 19″ RACK(2U).
- Possibility to be used without installation into the RACK(rubber feet).
MODEL | PD 332 |
---|---|
Power Requirements | ~380 V (single-phase) |
Output Power Sockets Number | 3 + 1 (по одной на фазу + одна дополнительная) |
Количество блоков наборных клемм (LNE) | 3 (по одному на фазу) |
Максимально допустимый длительный ток нагрузки на одну розетку | 16 А |
Максимально допустимый ток нагрузки на клемму | 32 А |
Максимальное сечение провода для подключения к клемме | 6 кв. мм |
Максимально допустимый длительный ток нагрузки | 32 А (по каждой фазе) |
Ток срабатывания основных автоматических выключателей | 32 А |
Ток срабатывания автоматического выключателя дополнительной розетки | 16 А |
Weight | 3.5 kg |
Height required in the RACK 19” | 2U |
Dimensions: | |
- width | 482 mm |
- height (withot feet) | 88 mm |
- height with feet | 96 mm |
- depth | 185 mm |
- depth in the RACK | 133 mm |
Empty tab. Edit page to add content here.